HP1700 Series

High purity two stage regulator available in brass or stainless steel, for use with non corrosive and mild corrosive gases and mixtures up to N6.0 purity. Advanced features make it suitable for the most demanding analytical requirements. This regulator can withstand vacuum applied to evacuate the system. Accepting inlet pressures up to 230bar (with a choice of gauges to suit lower cylinder pressures), it has a choice of delivery pressure ranges from 0 – 0.7bar, to 0 – 17bar.


Features

HP1700 series
  • Bar stock brass or stainless steel body
  • Hastelloy diaphragm with metal to metal seal for high leak integrity
  • Precise, accurate pressure control
  • Quick purging due to low internal volume and internally threadless nozzle assembly
  • 10 micron inlet filter for increased reliability
  • Bonnets threaded for panel mounting
  • Standard supply includes:

Inlet connection and gauge

Outlet gauge, outlet valve, outlet relief valve and compression fitting

Specification

  • Body:  bar stock brass or 316 stainless steel  
  • Seat:  regulator - PCTFE  . relief valve - Viton® (Neoprene® fitted for NH3) 
  • Diaphragm: Hastelloy C-22® 
  • Maximum inlet pressure:  230 bar (with a 300bar inlet gauge) or as limited by inlet gauge and components
  • Flow rate:  Cv = 0.06 
  • Operating temperature:   -40°C to +65°C 
  • Weight:  2.5kg  (approx). Dimensions (mm): 235(W)x140(H)x190(D)
Select the model you require
Model Material Outlet Pressure Bar (psi) Outlet Gauge Bar (psi) Relief Valve Setting Bar (psi)
HP1700-10 B (brass) or S (stainless) 0.1-0.7 (1-10) -1-1 (vac - 15) 1 (15)
HP1700 B (brass) or S (stainless) 0.1-2 (1-30) -1-4 (vac - 60) 4 (60)
HP1701 B (brass) or S (stainless) 0.1-5.2 (1-75) -1-7 (vac-100) 7 (100)
HP1702 B (brass) or S (stainless) 0.2-17 (3-250) 0-28 (0-400) 21 (300)
Additional options
Option Use Models available
Purge Assembly To purge toxic, corrosive or high purity gases from regulator body to prevent accidental exposure and maintain process gas purity Body Purge (P), Cross Purge, lever (LPS)
Non return Valve Allows flow in one direction. Prevents flow in reverse direction C-Check valve
Filter Particle removal down to 0.3 micron FBT(inlet), FBL (outlet)

How to order

ALWAYS specify gas or mixture to be used:

  1. select model e.g. HP1700, HP1701
  2. select material  e.g. brass, stainless steel
  3. select inlet gauge:  to match cylinder or line pressure e.g. GG (300 bar), GL (100 bar brass, 66 bar stainless steel), E (26 bar), U (13 bar)
  4. select inlet connection e.g. BS3, DIN 1
  5. select any inlet options e.g. body purge, cross purge, filters (pressure rating dependent)
  6. select outlet connection e.g. 1/4" compression fitting (standard), other fittings are available
  7. select any outlet options e.g. filters
For further information call 0800 02 0800 or email usFor further information email us