The LAS PDS changeover manifold is designed to connect two cylinders to a single outlet, allowing continuity of supply whilst an empty cylinder is changed. For helium, nitrogen and carbon dioxide lasing gases.
Features
- Automatic changeover manifold for continuity of gas supply
- Effective two stage regulation for controllable and stable outlet pressures
- Stainless steel diaphragms
- Flexible hoses with non return valves to connect to cylinders
- Interstage relief valve
- Delivery pressures to 8 bar with outlet pressure gauge (13 bar)
Specification
- Body: Chrome plated forged brass
- Valve seat/seals: Brass,viton
- Seat return spring: Stainless steel
- Filter: 10 micron stainless steel
- Seals: Nylon
- Operating temperature: -17 to +57°C
- Dimensions: 230 x 250mm excluding hoses
- Maximum inlet pressure: 207 bar
- Flow rate: Cv=0.05
Select the model you require:
Model | Outlet pressure bar (psi) | Relief valve setting bar (psi) | Changeover pressure bar |
---|---|---|---|
LAS PDS | 0-8.6 (0-125) | set to open at 27 bar (400 psi) | 11.3 - 13.7 |
Additional options
Standard Supply
600mm flexible hoses with cylinder connections and non return valves
Cylinder contents gauges
Automatic changeover unit and final regulator
Outlet pressure gauge
1/4"compression fitting outlet
Options
HI-Inlet isolation valve
IV-Isolation valve on outlet
R-Outlet relief valve
How to order
ALWAYS specify gas or mixture to be used:
- Select model eg.LAS PDS
- Select inlet connection eg.BS3
- Select outlet connection eg.1/4" compression fitting (for copper tube)
- Select any options eg.HI,IV,R